402-Fixture Wires: Page 2 of 3

You are here

Extruded

polytetraflu- oroethylene

— flexible

stranding

26-36 (AWG

silver or nickel-

coated copper)

PTFF

Extruded

polytetraflu- oroethylene

18-14 0.51

20

None

I50°C

302°F

Fixture wiring

(silver or nickel-coated copper)

Heat-resistant

rubber- covered fixture wire

— solid or

7-strand

RFH-1

Heat-resistant rubber

18 0.38

15

Nonmetallic covering

75°C I67°F

Fixture wiring

— limited to

300 volts

Heat-resistant

rubber- covered fixture wire

— solid or

7-strand

RFH-2

Heat-resistant rubber Cross- linked synthetic polymer

18-16 0.76

30

None or non- metallic covering

75°C

167°F

Fixture wiring

Heat-resistant

cross-linked synthetic polymer-insu- lated

fixture wire

— solid or 7-

strand

RFHH-2*

RFHH-3*

Cross-linked

synthetic polymer

18-16 0.76

18-16 1.14

30

45

None or non-

metallic covering

90°C

194°F

Fixture wiring

Silicone

insulated fixture wire

7-strand

SF-1

Silicone rubber

18 0.38

15

Nonmetallic covering

200°C

392°F

Fixture wiring

— limited to

300 volts

Silicone

insulated fixture wire

7-strand

SF-2

Silicone rubber

18-12 0.76

10 1.14

30

45

Nonmetallic covering

200°C

392°F

Fixture wiring

Silicone

insulated fixture wire

stranding

SFF-1

Silicone rubber

18 0.38

15

Nonmetallic covering

150°C

302°F

Fixture wiring

— limited to

300 volts

Silicone

insulated fixture wire

stranding

SFF-2

Silicone rubber

18-12 0.76

10 1.14

30

45

Nonmetallic covering

150°C

302°F

Fixture wiring

Thermoplastic

covered fixture wire

— solid or

7-strand

TP*

Thermoplastic

18-16 0.76

30

None

60°C I40°F

Fixture wiring

Thermoplastic

covered fixture wire

— flexible stranding

ypp*

Thermoplastic

18-16 0.76

30

None

60°C

140°F

Fixture wiring

(Continues)

Table 402.3 Continued

Name

Type

Letter

Insulation

Thickness of Insulation

Outer

Covering

Maximum

Operating

Temperature

Application

Provisions

Name

Type

Letter

Insulation

AWG mm

mils

Outer

Covering

Maximum

Operating

Temperature

Application

Provisions

Heat-resistant thermoplastic covered

fixture wire — solid or 7- strand

TFN*

Thermoplastic

18-16 0.38

15

Nylon-jacketed or equivalent

90°C

194°F

Fixture wiring

Heat-resistant thermoplastic covered

fixture wire — flexible stranded

TFFN*

Thermoplastic

18-16 0.38

15

Nylon-jacketed or equivalent

90°C

194°F

Fixture wiring

Cross-linked polyolefin insulated fixture wire — solid or 7- strand

XF*

Cross-linked polyolefin

18-14 0.76

12-10 1.14

30

45

None

150°C

302°F

Fixture wiring

— limited to

300 volts

Cross-linked polyolefin insulated fixture wire — flexible stranded

XFF*

Cross-linked polyolefin

18-14 0.76

12-10 1.14

30

45

None

150°C

302°F

Fixture wiring

— limited to

300 volts

Modified ETFE

— solid or 7-

strand

ZF

Modified ethylene tetrafluoro- ethylene

18-14 0.38

15

None

150°C

302°F

Fixture wiring

Flexible stranding

ZFF

Modified ethylene tetrafluoro- ethylene

18-14 0.38

15

None

150°C

302°F

Fixture wiring

High temp. modified ETFE — solid or 7-strand

ZHF

Modified ethylene tetrafluoro- ethylene

18-14 0.38

15

None

200°C

392°F

Fixture wiring

*Insulations and outer coverings that meet the requirements of flame retardant, limited smoke, and are so listed shall be permitted to be marked for limited smoke after the Code type designation.

402.5 Allowable Ampacities for Fixture Wires. The al- lowable ampacity of fixture wire shall be as specified in Table 402.5.

No conductor shall be used under such conditions that its operating temperature exceeds the temperature specified in Table 402.3 for the type of insulation involved.
FPN: See 310.10 for temperature limitation of conductors.

Table 402.5 Allowable Ampacity for Fixture Wires